Jump to content
Main menu
Main menu
move to sidebar
hide
Navigation
Main page
Recent changes
Random page
freem
Search
Search
Appearance
Create account
Log in
Personal tools
Create account
Log in
Pages for logged out editors
learn more
Contributions
Talk
Editing
Openai/683df711-c7b8-8004-a270-9f6cc034c12c
(section)
Add languages
Page
Discussion
English
Read
Edit
Edit source
View history
Tools
Tools
move to sidebar
hide
Actions
Read
Edit
Edit source
View history
General
What links here
Related changes
Special pages
Page information
Appearance
move to sidebar
hide
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
===== ✅ Step-by-Step Fix and Diagnostics ===== # Verify Battery Voltage - Use multimeter at the battery bank terminals (RELiON): confirm ≥12.8V. - If voltage <12V: charge externally via 120V charger or vehicle alternator until full. # Check BMPro Main Power Feed - Locate the BMPro “Node” or “Power Distribution Module” (usually near fuse box or behind main cabinet). - Test for 12V input to the unit with the multimeter. - If no 12V present: trace back to inline fuse or 12V cutoff relay — replace fuse or confirm relay is closed. # Check for Blown Fuse at BMPro System - There’s typically a dedicated fuse labeled “Control” or “BMPro” — verify continuity or replace with known good 10A fuse. # Reset the Lithium Batteries - For RELiON InSight batteries: - Locate the power button (often hidden on the end panel). - Hold for 3–5 seconds to initiate wake cycle. - LED indicator should turn green (if not, consult InSight manual for internal BMS fault). # BMPro Touchscreen or App Soft Reset - Hold the touchscreen power button (if equipped) for 10 seconds. - If using a remote key fob or app module (Node BLE), open/close the entry door 3x within 15 seconds to trigger wake command. # Pull Battery Disconnect for 5 Minutes - Open battery compartment. - Disconnect negative battery terminal (or use master disconnect if installed). - Wait 5 minutes — reconnect — check if BMPro initializes. # Manually Power the BMPro Panel - If accessible, apply 12V to the BMPro panel's input wire directly (bypassing fuse temporarily for test purposes). - If panel lights up: wiring/fuse issue confirmed. # Check DC-DC Charger and Solar Controller Wiring - Verify solar controller isn’t backfeeding erroneous voltage into system signal wires. - Disconnect temporarily if system appears unstable.
Summary:
Please note that all contributions to freem are considered to be released under the Creative Commons Attribution-ShareAlike 4.0 (see
Freem:Copyrights
for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource.
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)